INTRODUCTION

After the launch of the JUUL device on the US market in 2015, retail sales increased over the following three years, and the device became the best selling e-cigarette with 40% of the retail market share1. As a result of marketing and advertising strategies, JUUL became the e-cigarette brand used by over half of middle and high school students2, and its widespread use among young people led to much discussion in the entire field of healthcare providers, not just among pediatricians. Besides advertising, this discussion referred to the lack of information about the health risks that may be associated with e-cigarettes and other nicotine delivery devices3. As a result of the popularity of e-cigarettes among young people and the outbreak of e-cigarette or vaping product use-associated lung injury (EVALI) in October 20194, the FDA passed a legislative decision in January 2020 that tobacco products may be sold only to people aged ≥21 years5.

The large market share of e-cigarettes and their popularity among young people in the US increased interest not only in the question of long-term harm but also the gateway hypothesis6. Studies have shown that vaping may increase the risk of initiation of cigarettes, especially among teenagers7,8. Smoking is still one of the leading causes of mortality in Germany and is responsible for 110000–140000 premature deaths9. The levels of many hazardous and potentially hazardous substances are significantly lower in e-cigarette emissions than in cigarette smoke, leading to a reduced exposure to these compounds while vaping10,11. Thus, e-cigarette use is expected to reduce the risks for some diseases, especially cancer, and therefore JUUL and other kinds of e-cigarettes have started to be used as tools for smoking cessation12. However, e-cigarettes still deliver nicotine, so their use is less likely to reduce the rate of cardiovascular diseases, although this aspect requires further research.

In general, smoking has been described as one of the most important risk factors for cardiovascular events13,14, but it is also one of the most modifiable risk factors15. Several studies evaluated the chronic effects of smoking on cardiovascular events. To assess subclinical end-organ damage, the European Society of Hypertensiology and European Society of Cardiology recommend measuring arterial stiffness and endothelial dysfunction, parameters that also provide some initial indications of the onset of systemic cardiovascular disease16. A clear association between smoking and the increase in arterial stiffness is known15,17 and several studies have shown the rise in arterial stiffness of both e-cigarettes and heated tobacco products18-20. Some evidence shows that e-cigarettes, which are often marketed as a healthier smoking alternative21, can indeed increase cardiovascular risks. For example, Alzahrani et al.22 found that non-daily and in particular daily e-cigarette use increased the risk of myocardial infarction. However, a recent epidemiological analysis did not confirm increased cardiovascular risks for vapers who never smoked cigarettes23. Because conclusive evidence is still limited24, more data and analyses are required, especially for devices that deliver high levels of nicotine, such as the JUUL25. Although JUUL pods sold in the US contain up to 58 mg/mL of nicotine, the maximum concentration of nicotine in e-liquids allowed in the European Union is 20 mg/mL26. Therefore, in the European Union conventional JUUL pods were replaced by what JUUL lab employees supposedly refer to as ‘Turbo JUUL’ which uses different wick material27. A study on the Turbo JUUL found that the new wick material increased the amount of vapor generated and subsequently increased the amount of nicotine released per puff25.

To date, information is lacking on the effects of JUUL use on the pathogenesis of cardiovascular diseases, specifically on arterial stiffness and endothelial dysfunction. Therefore, we aimed to compare the acute effects on peripheral and central blood pressure and arterial stiffness of the new and old JUUL devices and conventional cigarettes, assuming that the use of the European JUUL versions as well as cigarette consumption increases the respective parameters.

METHODS

Study cohort and design

This single-center, three-arm study included 15 active smokers and 17 active e-cigarette users. A total of 39 measurements were performed, whereby the e-cigarette users were mostly tested in both the old and the new JUUL groups in order not to offer an entry into ‘dual use’ which seems to be a possible potentiation of health risks28. Participants were recruited from the population of the city of Munich by advertising and were assigned to the tobacco cigarette group or one of the two JUUL groups (old and new JUUL technology) according to the product that they normally used. At screening, inclusion criteria were checked as follows: 1) smoker or vaper, 2) no mental disorder, 3) no cardiovascular disease, 4) no thyroid disease, 5) no diabetes, 6) no abnormalities in physical examination, 7) no hypertension, and 8) no hypercholesterolemia. In addition, a pregnancy test was performed to exclude possible pregnancies in women who were not taking oral contraception. The measurements were made during the same phase of the menstrual cycle or pill period. All participants were asked to follow the guidelines for measuring arterial stiffness29,30. Therefore, cigarette smoking and nicotine intake in general were prohibited for the 12 hours before the study visit. The smoke-free time was tested by a Micro+Smokerlyzer™ (Bedfont Scientific Ltd., England) with a cut-off of 5 ppm carbon monoxide. In e-cigarette users, concentrations in the baseline blood sample were checked for possible elevated nicotine concentration. Participants were excluded if they declared that they were strict non-smokers. All participants provided written informed consent. The study was approved by the ethics committee of the LMU Munich (Amendment to project number 72-15) and performed in accordance with the principles of the Declaration of Helsinki in the currently valid version and was registered at the German Clinical Trials Register (DRKS, www.drks. de, registration number DRKS00017432). It was conducted according to the World Medical Association Declaration of Helsinki.

The three different study arms used the following products: 1) a commercial, combustible tobacco cigarette (Cig group; Marlboro Red, Philip & Morris, 0.8 mg nicotine); 2) a JUUL e-cigarette with the new technology (new JUUL group); and 3) a JUUL e-cigarette with the old technology (old JUUL group). The use of the JUUL device was explained to participants in groups 2) and 3) on the basis of the producer’s manual and vapers who were inexperienced in the use of JUUL e-cigarettes were trained in their use before the study. JUUL Pods with the flavor ‘Rich Tobacco’ were used and vegetable glycerol (VG), propylene glycol (PG), nicotine, benzoic acid and ‘aromas’ are specified as ingredients by the manufactor. Both the old and the new JUUL pods do not seem to differ much in the composition of ingredients. The VG/PG ratio is approximately 2:1 (w/w)25. All participants had to consume the respective product depending on the group affiliation at a frequency of 1 puff every 30 s for 10 puffs, with a puff duration of 3 s, as described in other publications31.

During the consumption sessions in the tobacco cigarette and new/modified JUUL arms, electroencephalography (EEG) measurements and blood samples for nicotine concentration during and after consumption were taken. Results on EEG and nicotine concentration in venous blood will be analyzed and published separately.

Generally, measurements were started at least 15 minutes before smoking or JUUL use. Peripheral and central hemodynamics were measured by the Mobil-O-Graph™ (I.E.M., Stollberg, Germany)32-34 before and at three times after using the specific device: at 5 minutes, 15 minutes, and at 30 minutes.

Measurement of peripheral and central blood pressures and arterial stiffness

Blood pressure and additional variables were measured with the validated Mobil-O-Graph™ (software version HMS CS 4.2, I.E.M. GmbH), which allows peripheral and central blood pressures, heart rate and arterial stiffness to be recorded32,33,35. Like many other devices, the Mobil-O-Graph™ uses the oscillometric technique in which a standard blood pressure cuff is placed at the arteria brachialis32. Besides the peripheral blood pressure, heart rate is also measured using the oscillometric technique. Central systolic blood pressure is determined from brachial waveforms which are recorded with the cuff at the level of diastolic blood pressure and processed with the ARCSolver transfer function. In addition, stroke volume and total peripheral resistance are calculated via a transfer function similar to the ARCSolver transfer function32. The derived central waveforms are used for pulse waveform analysis and the augmentation index and augmentation pressure are derived from them33,34. The augmentation index is adjusted for a heart rate of 75 beats per minute (bpm). After participants had rested for a short period, measurements were made at least 15 minutes before participants smoked or vaped in a sitting position. These data were used as a baseline and as references for statistical analyses.

Statistical analysis

Statistical analyses and graph editing were performed with SPSS statistical software (SPSS 23 Inc., Chicago, IL, USA) and GraphPad Prism 4 (GraphPad Software Inc., San Diego, CA, USA), respectively. Baseline mean values of blood pressure and arterial stiffness were used as statistical references.

Before further analysis, peripheral and central blood pressures were analyzed for normal distribution by Kolmogorov-Smirnov tests. Because of the longitudinal design, we used a two-way repeated-measures analysis of variance (ANOVA) to evaluate the effect of time. Accordingly, if we found no interaction we performed post hoc tests (Bonferroni) with G*Power. Also, we analyzed the data with a paired Student’s t-test or Wilcoxon rank sum test, as appropriate, to compare measurements at the four times. Where applicable, we performed a multivariate analysis of variance (MANOVA) correcting for age, mean arterial pressure (MAP), heart rate (HR), and sex. If not otherwise stated, all data are expressed as mean ± SD. A p<0.05 was considered statistically significant.

RESULTS

Baseline characteristics

Baseline characteristics for all 32 participants are presented in Table 1 and the flow of participants through the study is shown in Figure 1. The nicotine levels for the three groups with the corresponding numbers of participants are shown in Figure 2 36.

Table 1

Baseline characteristics of participants (N=39)

CharacteristicsMean ± SD
Sex, n
Male23
Female16
Age (years)32 ± 9.8
median (25% percentile; 75% percentile)29 (25; 39)
Height (m)1.75 ± 0.08
Weight (kg)72.9 ± 11.1
BMI (kg/m²)23.7 ± 3.3
Figure 1

Consort flow chart of participants

https://www.tobaccoinduceddiseases.org/f/fulltexts/144317/TID-20-34-g001_min.jpg
Figure 2

Plasma nicotine levels. Data are expressed as mean (SEM)

https://www.tobaccoinduceddiseases.org/f/fulltexts/144317/TID-20-34-g002_min.jpg

Peripheral systolic blood pressure and peripheral pulse pressure

At the initial measurement after 5 minutes, peripheral systolic blood pressure (pSBP) increased significantly by more than 3% in all three groups (p<0.05; Figure 3A, Table 2). In the JUUL new (+2%) and JUUL old groups (+9%), it remained elevated after 15 minutes (p<0.05; Figure 3A, Table 2).

Table 2

Effects of cigarette smoking and JUUL use on cardiovascular parameters

MeasurementsCigarette (n=15)
Baseline5 Minutesp15 Minutesp30 Minutesp
Mean ± SDMean ± SDMean ± SDMean ± SD
pSBP (mmHg)129.5 ± 11.3133.9 ± 10.60.0179127.9 ± 10.60.4744125.7 ± 12.30.0843
pDBP (mmHg)81.7 ± 10.385.9 ± 8.50.055182.8 ± 8.10.669083.3 ± 7.40.4406
pMAD (mmHg)103.1 ± 10.6107.5 ± 8.10.0326103.7 ± 7.50.6882102.7 ± 8.30.7757
pPP (mmHg)42.4 ± 10.051.2 ± 13.10.034245.1 ± 11.30.368544.2 ± 8.40.5757
HR (bpm)67.2 ± 13.481.5 ± 14.90.000274.9 ± 13.70.028771.2 ± 10.40.1375
cSBP (mmHg)113.1 ± 14.4119.9 ± 11.10.0261115.1 ± 10.90.3683112.7 ± 11.40.8797
cDBP (mmHg)83.0 ± 10.388.5 ± 7.90.003984.4 ± 7.50.509384.7 ± 7.60.3126
cPP (mmHg)27.1 ± 8.834.2 ± 9.00.014930.8 ± 8.20.098528.1 ± 8.10.7182
AIx@75 (%)9.3 ± 10.418.4 ± 10.80.000314.5 ± 11.50.06899.5 ± 9.50.9517
PWV (m/s)5.4 ± 0.55.7 ± 0.40.02875.5 ± 0.40.11405.4 ± 0.40.9484
SV (mL)65.3 ± 12.475.5 ± 15.00.013675.6 ± 16.60.010473.2 ± 14.30.0940
TPR (mmHg×min/L)1.2 ± 0.21.3 ± 0.20.00351.2 ± 0.20.27111.2 ± 0.20.7744
MeasurementsJUUL new technology (n=15)
Baseline5 Minutesp15 Minutesp30 Minutesp
Mean ± SDMean ± SDMean ± SDMean ± SD
pSBP (mmHg)123.4 ± 10.8127.4 ± 10.80.0181126.2 ± 10.90.0455121.6 ± 15.10.8312
pDBP (mmHg)80.2 ± 13.080.1 ± 9.20.141278.9 ± 9.20.365478.2 ± 10.50.6455
pMAD (mmHg)99.4 ± 10.5101.6 ± 8.40.0086100.6 ± 8.40.035198.2 ± 10.90.5725
pPP (mmHg)41.2 ± 9.151.2 ± 14.80.008447.3 ± 10.70.029043.5 ± 13.90.5989
HR (bpm)70.7 ± 14.677.0 ± 14.60.013974.1 ± 13.50.208669.3 ± 9.60.9500
cSBP (mmHg)113.2 ± 11.2115.2 ± 8.70.0096115.7 ± 7.50.0076112.6 ± 13.60.4840
cDBP (mmHg)82.4 ± 13.083.3 ± 8.80.008780.2 ± 9.40.664679.6 ± 10.60.9111
cPP (mmHg)29.2 ± 6.134.3 ± 11.40.075535.2 ± 9.30.005533.2 ± 10.90.1242
AIx@75 (%)13.7 ± 12.316.1 ± 10.60.004513.3 ± 11.30.235011.0 ± 8.80.1157
PWV (m/s)5.9 ± 1.15.9 ± 0.90.00886.0 ± 0.80.01405.9 ± 1.00.6367
SV (mL)66.4 ± 14.376.8 ± 16.50.005280.3 ± 19.20.012077.6 ± 20.10.0606
TPR (mmHg×min/L)1.2 ± 0.21.3 ± 0.10.00571.1 ± 0.20.23471.2 ± 0.30.4350
MeasurementsJUU L old technology (n=15)
Baseline5 Minutesp15 Minutesp30 Minutesp
Mean ± SDMean ± SDMean ± SDMean ± SD
pSBP (mmHg)122.6 ± 17.9133.4 ± 14.50.0292133.6 ± 16.00.0473122.2 ± 6.90.9130
pDBP (mmHg)77.9 ± 13.881.2 ± 14.20.162881.3 ± 19.10.436472.8 ± 12.50.9710
pMAD (mmHg)99.5 ± 14.1104.0 ± 11.80.0687105.2 ± 14.80.029295.3 ± 9.50.7214
pPP (mmHg)41.7 ± 15.055.2 ± 15.10.012552.3 ± 20.00.191149.3 ± 8.80.8258
HR (bpm)72.9 ± 7.779.4 ± 11.40.034678.7 ± 9.30.047168.2 ± 3.80.3653
cSBP (mmHg)111.8 ± 16.0119.9 ± 15.50.0734119.4 ± 16.00.0291113.4 ± 6.90.8142
cDBP (mmHg)79.3 ± 14.285.3 ± 14.50.006189.0 ± 17.90.037375.2 ± 13.40.9668
cPP (mmHg)30.5 ± 10.936.9 ± 12.40.109132.7 ± 9.10.725930.0 ± 6.10.4632
AIx@75 (%)11.6 ± 4.323.5 ± 5.70.001121.6 ± 7.90.002017.8 ± 17.50.4229
PWV (m/s)5.8 ± 1.16.0 ± 1.00.03495.8 ± 1.00.04675.8 ± 0.80.9423
SV (mL)64.1 ± 16.070.4 ± 8.60.005869.9 ± 19.60.085765.7 ± 4.10.3907
TPR (mmHg×min/L)1.2 ± 0.21.3 ± 0.20.13341.4 ± 0.20.02301.2 ± 0.30.8541
Figure 3

a) Peripheral systolic blood pressure (pSBP), b) peripheral diastolic blood pressure (pDBP), c) peripheral pulse pressure (pPP), and d) heart rate (HR). Asterisks indicate a significant change of individual values from baseline. Data are expressed as mean (SD)

https://www.tobaccoinduceddiseases.org/f/fulltexts/144317/TID-20-34-g003_min.jpg

pDBP did not change significantly in either cigarette (Cig) or the old JUUL group (p>0.05; Figure 3B, Table 2) or the new JUUL group (p>0.05; Figure 3B, Table 2).

Peripheral mean arterial pressure (pMAP) increased significantly in the Cig (+4%) and new JUUL (+2%) groups after 5 minutes, and in the new JUUL (+ 1%) and old JUUL (+5%) groups after 15 minutes (each p<0.05; Table 2).

Peripheral pulse pressure (pPP) increased significantly, by more than 20%, in all three study groups after 5 minutes (p<0.05; Figure 3C, Table 2) and by 14% in the new JUUL group after 15 minutes (p<0.05; Figure 3C, Table 2).

HR

After 5 minutes, HR increased significantly, by more than 8%, in all three study groups (each p<0.05; Figure 3D, Table 2). HR remained significantly increased after 15 minutes in the Cig and old JUUL groups (each p<0.05; Figure 3D, Table 2).

Central blood pressure

After the first 5 minutes, central systolic blood pressure (cSBP) increased significantly, by more than 6%, in the Cig group (p<0.05; Figure 3A, Table 2) and more than 1% in the new JUUL group (p<0.05; Figure 4A, Table 2). After 15 minutes, cSBP remained elevated in both JUUL groups (new JUUL +2%; old JUUL +6%; each p<0.05; Figure 4A, Table 2).

Figure 4

a) Central systolic blood pressure (cSBP), b) central pulse pressure (cPP), and, as measures of arterial stiffness, c) augmentation index adjusted for a heart rate of 75 beats per minute (AIx@75) and d) pulse wave velocity (PWV). Asterisks indicate a significant change of individual values from baseline. Data are expressed as mean (SD)

https://www.tobaccoinduceddiseases.org/f/fulltexts/144317/TID-20-34-g004_min.jpg

Central diastolic blood pressure (cDBP) was significantly increased after 5 minutes in the Cig (+6%), new JUUL (+1%), and old JUUL (+7%) groups (each p<0.01; Table 2), and after 15 minutes remained elevated in the old JUUL group (+12%; p<0.05; Table 2).

Central pulse pressure (cPP) increased significantly, by more than 20%, in the Cig group after 5 minutes and by more than 20% in the new JUUL group after 15 minutes (each p<0.05; Figure 4B, Table 2).

Arterial stiffness and total peripheral resistance

The augmentation index adjusted for a heart rate of 75 bpm (AIx@75) increased significantly in the Cig (+97%), new JUUL (+17%), and old JUUL groups (+102%) after 5 minutes and in the old JUUL group (+86%) after 15 minutes (each p<0.01; Figure 4C, Table 2). After performing a multivariate analysis of AIx@75 including blood pressure and heart rate, in all three groups changes remained significant (Box test, each p>0.05; Levene test, each p<0.05; Wilks’ lambda [multivariate test], each p<0.05).

The pulse wave velocity (PWV) showed a significant change after 5 minutes in the Cig (+5%), new JUUL (+1%), and old JUUL (+2%) groups and after 15 minutes in the new JUUL (+1%) and old JUUL (+1%) groups (each p<0.05; Figure 4D, Table 2).

Stroke volume (SV) increased significantly, by more than 15%, in the Cig group, by more than 15% in the new JUUL group, and by more than 9% in the old JUUL group after 5 minutes, and by more than 15% in the Cig and by more than 20% in the new JUUL groups after 15 minutes (each p<0.05; Table 2).

Total peripheral resistance (TPR) increased after 5 minutes in the Cig (+11%) and new JUUL (+4%) groups and after 15 minutes in the old JUUL group (+16%) (each p<0.05; Table 2).

DISCUSSION

To the best of our knowledge, this study is one of the first to compare the impact of vaping the European JUUL version and cigarette smoking on peripheral and central hemodynamics and arterial stiffness37-41. In particular, the effects on arterial stiffness of JUUL use were as yet unknown, although recent studies have shown that heart rate as well as mean arterial pressure are influenced by vaping the American JUUL version42. This is in accordance with our data which showed acute increases in peripheral and central blood pressure for a short period after both JUUL use and smoking.

Recently published studies provided a contradictory picture with regard to arterial stiffness after vaping and smoking18,38,39,43. In line with our previously published study on e-cigarettes, Franzen et al.18 and Vlachopoulos et al.39 showed an impact of vaping on central hemodynamic and peripheral blood pressure. As expected and already published18,38,39,43, heated tobacco products, cigarettes, and e-cigarettes with nicotine-containing liquids lead to an increase of peripheral and central hemodynamic parameters and arterial stiffness. For the JUUL device, we were also able to show an increase in peripheral and central hemodynamics that was comparable to the changes found with combustible cigarettes. With regard to these parameters, only minor differences were found between the new and old JUUL technology.

In line with the previously published trials, AIx@75 increased significantly after JUUL use. As another parameter of arterial stiffness, we showed significant raises in PWV in the combustible cigarette and JUUL groups. These temporary alterations of hemodynamic and arterial stiffness are likely triggered by nicotine as an acute vasoconstrictor and also by local and circulating catecholamines which are released during nicotine consumption. These catecholamines also indicate the activity and stimulation of sympathetic ganglia, among other things. As a consequence of the stimulation due to nicotine, sympathetic neuronal discharge-impaired nitric oxide production increases in the central nervous system, which in turn leads to an increase in arterial stiffness44-46. However, our results showed that a small part of the increase in arterial stiffness remained unexplained by the device, blood pressure, heart rate, or sex. This unexplained change might be due to the effects of the cigarette and JUUL on the endothelium. Therefore, a combination of nicotine and harmful or potentially harmful compounds in smoke and vapor is one of the most likely explanations for this observation. Similar results were shown in an animal model by Nabavizadeh et al.47 who compared combustible cigarettes with heated tobacco products. In addition, population-based studies on cardiovascular diseases found an association between e-cigarette use and increased risk of myocardial infarction22. However, the influence of former or current smoking is unclear. The pathogenesis of coronary heart disease and other cardiovascular events includes stiffening of the arteries34,48, an effect that could be shown here to occur with JUUL use. Besides central hemodynamics, arterial stiffness seems to be even more important than peripheral blood pressures as a surrogate parameter for cardiovascular events30,49,50. It should be noted that cigarette smoke not only affects the cardiovascular system but also has other negative effects on health, and e-cigarette aerosols contain much lower amounts of harmful and potentially harmful substances than cigarette smoke10,25,51. Thus, a complete switch from tobacco cigarettes to e-cigarettes is widely acknowledged to reduce the exposure to many carcinogens and other toxicologically relevant compounds11,52.

Limitations

Unlike the study by Vlachopoulos et al.39 on blood pressure and arterial stiffness which included four study arms, the present study included only three arms. Also, the sample size was limited, and a cross-over design was not used. In addition, participants were not randomized to the study arms, and only acute effects were assessed. Last, the intensity of JUUL use, i.e. the intensity of the puff, could not be standardized, although the frequency, number, and duration of puffs were defined to avoid large differences in vaping behavior. In this study, other measurements like EEG and blood samples were carried out in parallel to increase the information output. However, possible influences on the individual stress level of the participants could not be excluded.

Future research

Future studies should focus on the chronic effects of the JUUL device and compare them with the long-term effects of conventional e-cigarettes with nicotine-containing or nicotine-free liquids or combustible cigarettes. The literature describes neither endothelial dysfunction nor cardiac inflammation for JUUL use, so future studies should address these issues. Also, a head-to-head comparison of e-cigarettes, JUUL, heated tobacco products, and combustible cigarettes should be conducted and should focus on peripheral blood pressure, arterial stiffness, and endothelial dysfunction.

CONCLUSIONS

Comparable adverse changes for blood pressure, heart rate, and arterial stiffness parameters were shown between both smoking a filter cigarette and JUUL use. In our interpretation, these and especially the changes in arterial stiffness may be associated with increased cardiovascular risk. However, a long-term follow-up evaluation of JUUL use and a head-to-head comparison with conventional e-cigarettes are still needed.